Quality and validation

Turn a sensor reading into traceable process evidence

A credible moisture project links every displayed value to a defined reference method, representative samples and documented acceptance conditions.

Turn a sensor reading into traceable process evidence

Quality and validation

A traceable result is built as a chain

Skipping one link can make a stable-looking value unsuitable for control, quality release or settlement.

01

Define the measurand

Agree the material, wet or dry basis, measurement volume and decision to be supported.

02

Choose the reference

Use the applicable laboratory, oven or recognised industry method and record its conditions.

03

Plan sampling

Match online time and location while protecting samples from moisture loss or gain.

04

Build the dataset

Cover real moisture, density, temperature, formulation, particle size and seasonal variation.

05

Calibrate the model

Relate sensor response to reference results with a controlled model and version record.

06

Validate independently

Test data not used to build the model and compare results against pre-agreed criteria.

07

Verify in service

Monitor bias, process changes, maintenance and the triggers for revalidation or recalibration.

Quality and validation

Six workstreams behind calibration confidence

Each workstream answers a different risk. Together they define whether the result remains valid in the real process.

01

Reference method

Confirm method scope, sample preparation, drying or laboratory conditions, calculation basis and current revision.

02

Representative sampling

Cover space, time, depth, batch, supplier and process state; pair each sample with the correct online interval.

03

Dataset design

Include the full intended range and influential variables; separate model-building data from independent validation.

04

Performance evidence

Review bias, residuals, repeatability and errors by material group and operating range—not one headline number.

05

FAT and SAT

Document configuration, I/O, installation, communications, paired sampling, alarm logic and agreed acceptance tests.

06

Ongoing verification

Use routine comparison, trend review, change records and clear triggers for adjustment or full recalibration.

Quality and validation

What a complete validation package should contain

The package should allow another engineer or quality manager to understand what was tested, under which conditions and where the limits are.

  1. 01Reference-method agreement
  2. 02Sampling and dataset matrix
  3. 03Calibration and independent-validation report
  4. 04FAT/SAT and maintenance plan

Published performance must remain tied to the tested material and installation conditions.

Contact Us

Start validation planning before installation

Share the material, measurement point, reference method and intended decision so the sensor route, sampling access and acceptance plan can be designed as one system.

Prepare an application review

Tell us what you measure, where it moves and how the result will be used

Share a few process details and our application team will recommend a suitable technology, installation concept and validation plan.

Contact an engineer
WhatsApp